AVE DR8X Instalační příručka Strana 5

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 9
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 4
5
Dome Control
Dome Connection & Settings:
See section Connecting Your DVR
for RS-485 port pin definition.
Refer to the following figure. Connect the R+, R- terminals on the dome camera to the D+, D-
terminals on the RS-485 port by RS-485 cable respectively.
To set up dome protocol and ID, press MENU to access the Main menu, and select <Camera
Setup>. The available protocols include <DynaColor>, <Pelco D>, <Pelco P>, <AD422> and
<None> (default). Note that ID number must match the ID address defined by the dome.
To configure the RS-485 parameters, select <System Setup> from Main menu, and then select
<RS485 Setup>. The default
Full-Featured MPEG-4 series DVR RS-485 settings are 9600 Baud,
8 Data Bits, 1 Stop Bit and No Parity.
Dome Control Button:
Set / Go Preset
Toggle Hint
Screen
Iris Open
Focus Near
Zoom In
ESC
Auto / Enter
Iris Close
Focus Far
Zoom Out
Pan / Tilt
Zobrazit stránku 4
1 2 3 4 5 6 7 8 9

Komentáře k této Příručce

Žádné komentáře