• Area Threshold
<Area Threshold> indicates the motion alarm triggered level; if the
percentage of triggered grids to total detection area is greater than
the set value, the motion alarm will be triggered.
For example, if 10 grids are selected and the <Area Threshold>
value is 70%, the motion alarm will be triggered when seven grids
are motion detected.
Click UP / DOWN arrow keys to adjust the value. The value is
indicated in 4% increment.
Note that every time you have changed the value, remember to click
on “Apply” key to make the change take effect.
After the change(s) have been made (remember to click on “Apply”),
click to start detecting; click to stop detecting; click
to select all grids; and click to clear all selected
grids.
Alarm In
This item allows user to enable / disable alarm input detection. According to
your application, select <N/O> (Normal Open) or <N/C> (Normal Close) to
enable the alarm input detection or select <OFF> to disable the detection.
The default setting is <OFF>.
If you set this item to <N/C> but did not install any device to the unit, the alarm
will be triggered and the Event Icon displayed continually until this item is
changed to <N/O>, <OFF> or install a device to the unit.
Alarm Out
This item allows user to assign an alarm on certain channel to activate the
relays. These signals can be used to drive a light or siren to caution an alarm
event.
Select from the options: <A Only> indicates “Alarm Out A”, <B Only> indicates
“Alarm Out B”, <Both> indicates “Both Alarm Out” and <None> indicates “No
Alarm Out”. The default setting is <None>.
40