Installation
ADPRO FastTrace, Issue 5 1 - 17
The setup options for Alarm Inputs are described with reference to the ‘rest’ or non-alarm position of a set of switch
contacts:
Normally Open - needs a closing alarm contact to activate an alarm
Normally Closed - needs an opening alarm contact to activate an alarm
SEOL Normally Open - Single End of Line termination with N/O contacts
SEOL Normally Closed - Single End of Line termination with N/C contacts
DEOL Normally Open - Dual End of Line termination with N/O contacts
DEOL Normally Open - Dual End of Line termination with N/C contacts
WARNING
DO NOT attempt to solder directly onto the connector pins, as this may cause heat damage
to the connector housing or to the interface PCB.